Dokumentation DE
Documentation EN
Targeted at the Tesla Wall Connector Gen 3 available at https://shop.tesla.com/de_de/product/gen-3-wall-connector . Only provides read access to API data (write isn't supported by the API).
You can install the adapter via the ioBroker web interface.
- Open your ioBroker web interface in a browser (eg: 192.168.178.42:8081)
- Click on Tab "Adapters"
- Type "tesla-wallconnector3" in the filter
- Click on the "+" symbol of the Tesla Wall Connector Gen 3 adapter
Additional to the adapter installation you have to add an instance of the adapter.
- Open your ioBroker interface in a browser (eg: 192.168.178.42:8081) (if configuration dialogue was opened automatically after installation, skip to 4.).
- Navigate to Tab "Instances"
- Click on the wrench symbol of the Tesla Wall Connector Gen 3 adapter
- Now you can see the main settings of the adapter configuration page.
4.1 Type in the IP-address of your Tesla Wall Connector Gen 3 (FQDN is also possible if you have a working local DNS).
4.2 You can change the polling interval, too. (Default: 10 seconds)
4.3 If your network requires a higher timeout for requests sent to Tesla Wall Connector Gen 3, please change the Request-Timeout in miliseconds accordingly. (Default: 5000 miliseconds)
4.4 In case there is an issue communicating with Tesla Wall Connector Gen 3 the adapter will retry several times. You can adjust how often it will try to read from Tesla Wall Connector Gen 3. (Default: 10)
4.5 To space retries apart a bit more you can adjust the Polling Retry Factor. (Default: 2)
Example: Using default settings the 1st retry will happen 20 seconds after the initial try, the 2nd will happen 40 seconds after the 2nd try.
After each successful connect to Tesla Wall Connector Gen 3, the number of retries is reset. - Click on Save & Close
Here you can find a description of the states and how to use them. All states of this adapter are read-only states.
Please be aware that most (if not all) descriptions might be way off and might require confirmation or corrections. Pull-Requests with updates are welcome and encouraged!
-
info.connection
Data type Permission boolean R Read-only boolean which is true if the adapter is connected to the Tesla Wall Connector Gen 3.
-
alert_count
Data type Permission number R Read-only number, representing the number of alerts.
-
avg_startup_temp
Data type Permission number R Read-only number, representing if the average startup temperature.
-
charge_starts
Data type Permission number R Read-only string, representing the number of charging starts.
-
charging_time_s
Data type Permission number R Read-only number, representing the charging time in seconds of the WC3
-
connector_cycles
Data type Permission number R Read-only number, representing the number of connector cycles (plugging in and out most likely counting each as 1).
-
contactor_cycles
Data type Permission number R Read-only number, representing the number of state-changes of the relais so far.
-
contactor_cycles_loaded
Data type Permission number R Read-only number, representing the number of charging cycles.
-
energy_wh
Data type Permission number R Read-only number, representing the amount of energy supplied in Wh.
-
thermal_foldbacks
Data type Permission number R Read-only number, representing the ???
-
uptime_s
Data type Permission number R Read-only number, representing the uptime in seconds of the WC3
-
firmware_version
Data type Permission string R Firmware version on the Tesla Wall Connector Gen 3
-
part_number
Data type Permission string R Part number of the Tesla Wall Connector Gen 3
-
serial_number
Data type Permission string R Serial number of the Tesla Wall Connector Gen 3
-
current_alerts
Data type Permission string R Read-Only string with details about alerts.
-
contactor_closed
Data type Permission boolean R Read-Only boolean indicating if the relais is closed.
-
grid_hz
Data type Permission number R Read-Only number representing the grids frequency.
-
config_status
Data type Permission number R Read-Only number representing the config status. Please help with details!
-
current[A,B,C,N]_a
Data type Permission number R Read-Only number representing the current of line [A,B,C,N] in ampere.
-
evse_state
Data type Permission number R *Read-Only number representing the evse state. We seem to know so far: 0=booting, 1=idle, 2=connect but not ready, 3=???, 4=connected and ready, 5=???, 6=vehicle plugged in and handshaking, 7=???, 8=charging completed/interrupted, 9=ready for charging but waiting on car, 10=charging with reduced power (less than 3 phases, 16 amps each), 11=charging full power (3 Phases, 16 amps each), 12=??? *
-
grid_v
Data type Permission number R Read-Only number representing the grids voltage.
-
handle_temp_c
Data type Permission number R Read-Only number representing the handle's tempearture in °C.
-
input_thermopile_uv
Data type Permission number R Read-Only number representing ???.
-
mcu_temp_c
Data type Permission number R Read-Only number representing the master control unit's tempearture in °C.
-
pcba_temp_c
Data type Permission number R Read-Only number representing the printed circuit board's tempearture in °C.
-
pilot_high_v
Data type Permission number R Read-Only number representing the pilot line's high voltage.
-
pilot_low_v
Data type Permission number R Read-Only number representing the pilot line's low voltage.
-
prox_v
Data type Permission number R Read-Only number representing ???.
-
relay_coil_v
Data type Permission number R Read-Only number representing the relay coils voltage.
-
session_s
Data type Permission number R Read-Only number representing the duration of the current charging session in seconds.
-
session_energy_wh
Data type Permission number R Read-Only number representing the energy supplied in the current session in Wh.
-
uptime_s
Data type Permission number R Read-Only number representing the WC3's uptime in seconds.
-
vehicle_connected
Data type Permission boolean R Read-Only boolean indicating if a vehicle is connected.
-
vehicle_current_a
Data type Permission number R Read-Only number representing vehicles current in ampere.
-
voltage[A,B,C]_v
Data type Permission number R Read-Only number representing the voltage of line [A,B,C].
-
internet
Data type Permission boolean R Read-only boolean, representing if the Tesla Wall Connector Gen 3 is connected to the internet.
-
wifi_connected
Data type Permission boolean R Read-only boolean, representing if the Tesla Wall Connector Gen 3 is connected to wifi.
-
wifi_infra_ip
Data type Permission string R Read-only string, representing the IP of the Tesla Wall Connector Gen 3.
-
wifi_mac
Data type Permission string R Read-only string, representing the MAC address of the Tesla Wall Connector Gen 3.
-
wifi_rssi
Data type Permission number R Read-only number, representing the rssi of the wifi the Tesla Wall Connector Gen 3 is connected to.
-
wifi_signal_strength
Data type Permission number R Read-only number, representing the signal strength of the wifi the Tesla Wall Connector Gen 3 is connected to.
-
wifi_snr
Data type Permission number R Read-only number, representing the snr of the wifi the Tesla Wall Connector Gen 3 is connected to.
-
wifi_ssid
Data type Permission string R SSID the Tesla Wall Connector Gen 3 is connected to.
- Maintenance update (dependencies, ...)
MIT License
Copyright (c) 2024 Norbert Bluemle github@bluemle.org
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.