Usage of the module is very straight forward, include the module in your script and pass it an Opentherm message.

const parser = require('node-opentherm-parser')

console.log(parser('C000CCCC'))

The response is a JSON object of the form:

{
  msgType: { code: 4, text: 'Read-Ack' },
  dataId: { id: 0, name: 'Status' },
  properties: {
    fault: false,
    ch_active: false,
    dhw_active: true,
    flame_on: true,
    cooling_active: false,
    ch2_active: false,
    diagnostic: true,
    electricity_production: true
  }
}

where:

  • msgType is an object containing the numeric and textual representation of the type of message and can be one of:

    • Read-Data (0)
    • Write-Data (1)
    • Invalid-Data (2)
    • Reserved (3)
    • Read-Ack (4)
    • Write-Ack (5)
    • Data-Invalid (6)
    • Unknown-DataId (7)
  • dataId is the Opentherm data object containing the id and name

  • properties is an object containing all properties of the data object and their values

Supported Data objects and their properties

The following data objects and properties are supported by this module:

DataId Name Msg Type Properties Values
0 Master and slave status flags Read-Ack fault true/false
ch_active true/false
dhw_active true/false
flame_on true/false
cooling_active true/false
ch2_active true/false
diagnostic true/false
electricity_production true/false
Read-Data ch_enabled true/false
dhw_enabled true/false
cooling_enabled true/false
outside_temperature_correction_active true/false
ch2_enabled true/false
summer_winter_mode true/false
dhw_blocking true/false
1 Central heating control setpoint n.a. ch_setpoint number
2 Master configuration flags n.a. smartpower_supported true/false
master_memberidcode number
3 Slave configuration flags n.a. dhw_present true/false
onoff true/false
cooling_supported true/false
dhw_tank_present true/false
pump_control_allowed true/false
ch2_present true/false
remote_water_filling true/false
heat_cool_mode_control true/false
slave_memberidcode number
4 Command n.a. cmd_code number
cmd_resp_code number
5 Application specific fault flags n.a. service_required true/false
remote_reset_enabled true/false
water_pressure_fault true/false
gas_flame_fault true/false
air_pressure_fault true/false
water_over_temp true/false
oem_fault_code number
6 Remote parameter flags n.a. dhw_setpoint_tx_enabled true/false
max_ch_setpoint_tx_enabled true/false
dhw_setpoint_rw true/false
max_ch_setpoint_rw true/false
7 Cooling control n.a. cooling_signal true/false
8 Central heating setpoint 2nd circuit in °C n.a. ch2_setpoint number
9 Remote override room setpoint in °C n.a. override_room_setpoint number
10 Number of transparant slave parameters n.a. num_of_tsp true/false
11 Transparant slave parameter index/value n.a. tsp_index number
tsp_value number
12 Fault history buffer size n.a. fault_history_buffer_size number
13 Fault history buffer index/value n.a. fault_history_index number
fault_history_value number
14 Max. relative modulation levelg n.a. max_rel_mod_level number
15 Max. capacity / Min. modulation level n.a. max_capacity number
min_mod_lev number
16 Room setpoint in °C n.a. room_setpoint number
17 Rel. modulation level n.a. rel_mod_level number
18 Central heating water pressure in bar n.a. ch_pressure number
19 Domestic hot water flow rate in l/min n.a. dhw_flow_rate number
20 DayTime n.a. day_time day of week, time
21 Date n.a. date month, day of month
22 Year n.a. year year
23 Room setpoint 2nd cicuit in °C n.a. room2_setpoint number
24 Room temperature in °C n.a. room_temperature number
25 Boiler water temperature in °C n.a. ch_temperature number
26 Domestic hot water temperature in °C n.a. dhw_temperature number
27 Outside temperature in °C n.a. outside_temperature number
28 Return water temperature in °C n.a. return_temperature number
29 Solar storage water temperature in °C n.a. solar_storage_temperature number
30 Solar collector temperature in °C n.a. solar_collector_temperature number
31 Central heating flow temperature 2nd circuit in °C n.a. ch2_flow_temperature number
32 Domestic hot water setpoint 2nd circuit in °C n.a. dhw2_setpoint number
33 Exhaust temperature in °C n.a. exhaust_temperature number
35 Fan speed n.a. fan_speed number
36 Electrical current through burner flame n.a. burner_current number
37 Room temperature 2nd circuit in °C n.a. room2_temperature number
38 Relative humidity n.a.rel_humidity_1 number
rel_humidity_2 number
48 Hot water setpoint range n.a. dhw_setpoint_high number
dhw_setpoint_low number
49 Central heating setpoint range n.a. ch_setpoint_high number
ch_setpoint_low number
50 Hcratio-UB / Hcratio-LB n.a. heat_curve_ratio_ub number
heat_curve_ratio_lb number
56 Domestic hot water setpoint in °C n.a. dhw_setpoint number
57 Max. allowable central heating setpoint n.a. max_ch_setpoint number
58 Hcratio n.a. heat_curve_ratio number
100 Remote override function n.a. manual_priority true/false
schedule_priority number
115 OEM diagnostic code n.a. oem_service_code number
116 Burner starts n.a. burner_starts number
117 CH pump starts n.a. ch_pump_starts number
118 DHW pump / valve starts n.a. dhw_pump_starts number
119 DHW burner starts n.a. dhw_burner_starts number
120 Burner operation hours n.a. burner_hours number
121 CH pump operation hours n.a. ch_pump_hours number
122 DHW pump / valve operation hours n.a. dhw_pump_hours number
123 DHW burner operation hours n.a. dhw_burner_hours number
124 OpenTherm version Master n.a. otver_master number
125 OpenTherm version Slave n.a. otver_slave number
126 Master-version n.a. master_product_type number
master_product_version number
127 Slave-version n.a. slave_product_type number
slave_product_version number
131 Remeha dF-/dU-codes n.a. remeha_df_code number
remeha_du_code number
132 Remeha service message n.a. remeha_service_required None/Type A/Type B/Type C
133 Remeha detection connected SCU’s n.a. remeha_scu_part1 number
remeha_scu_part2 number

Readme

Keywords

none

Package Sidebar

Install

npm i node-opentherm-parser

Weekly Downloads

1

Version

0.1.5

License

MIT

Unpacked Size

35 kB

Total Files

6

Last publish

Collaborators

  • rklootwijk